Joints between segments were leaking, but the Client did not allow any drilling in the segments to seal them. The approved solution was a B Joint System with injections with KÖSTER Injection Gel S4 and KÖSTER B+.
First, a rubber joint is placed into the joint, after which injection is carried on through needles. After completion of this step, the system can be removed and placed into the next joint to seal it.